Product name : leakage protector, RCBO
Ampere : 16-100A
Rated voltage : 230V, 400V AC
Rated residual current : 10mA, 30mA, 100mA, 300mA
Protection type : Electromagnetic
Poles : 2P,4P
Residual current working type : AC, AC+S, A, A+S
Terminal connection type : cable, busbar
Electromagnetic leakage protector PR8NM 6kA RCBO 16-100A circuit breaker
The Electromagnetic Circuit Breaker Have Following Advatages:
1. Control electric circuits
2. Protect people against indirect contacts and additional protection against direct contacts
3. Protect installations against fire hazard due to insulation faults
4. Residual current circuit breakers are used in housing, tertiary sector and industry
5. Support 35mm Din-rail installation
Tripping sensitivity:
♦ 30 mA--additional protection against direct contact
♦ 100mA--co-ordinated with the earth system according to the formula In<50/R, to provide protection against indirect contacts
♦ 300mA, protection against indirect contacts, as well we fire hazard
Specifications:
Poles | 2P,4P |
Electrical Specification | |
Rated current (A) In | 16-100A |
Rated working voltage (V) Ue | 2P:230, 4P:400 |
Rated insulated voltage (V) Ui | 500 |
Impulse withstand voltage (kV) Uimp | 6 |
Rated short circuit breaking capacity (kA) Inc/I△n | 6 |
Rated residual current (mA) I△n | 10,30,100,300 |
Rated residual making and breaking capacity (A) I△m | 1000 |
residual current working type | AC,AC+S, A, A+S |
residual current protection type | Electromagnetic |
Dielectric test voltage(kV) | 2.5 |
Service life Mechanical Standard value | 4000 |
(O-C) Electrical Standard value | 2000 |
Control And indication | |
Shunt release (SHT) | NONE |
Undervoltage release (UVT) | NONE |
Auxiliary contact(AUX) | NONE |
Contact position indicator | NONE |
Fault indication | DEFAULT |
Connection And Installation | |
Ambient temperature (with daily average ≤35℃) | -5℃ ~ +40℃ |
Protection degree All sides | IP40 |
connection terminal | IP20 |
Wire(m㎡) | 35 |
Busbar (m㎡) | 35 |
Mounting | Cable/Busbar |
Reference temperature for setting of thermal element | 30 |
Pollution degree | 2 |
Storage temperature(℃) | -25℃ ~ +70℃ |
Connection | Top |
Dimensions(mm) a(2P/4P) | 36/72 |
b(2P/4P) | 84/84 |
c(2P/4P) | 79.5/79.5 |
Selection:
♦ Detectable wave form
♦ AC type
♦ A type
RCCB for which tripping ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowing rising, Symbol
Tripping time:
♦ Instantaneous: Instantaneous tripping can be ensured (without time-delay)
♦ Short time delay : Any tripping can be ensured at least 10ms
♦ Selective : Total discrimination with a nonselective RCD placed downstream are ensured.
Connection Diagram:
The diagram of distribution line:
![]() |